6.5.2

Setting frequency command characteristics

: VIA/II input point 1 setting
: VIA/II input point 1 frequency
: VIA/II input point 2 setting
: VIA/II input point 2 frequency
: VIB input point 1 setting (Frequency UP response time)
: VIB input point 1 frequency (Frequency UP step width)
: VIB input point 2 setting (Frequency DOWN response time)
: VIB input point 2 frequency (Frequency DOWN step width)
• Function
These parameters adjust the output frequency according to the externally applied analog signal
(0-10V dc voltage, 4-20mA dc current) and the entered command for setting an external contact
frequency.
Parameter setting
Title
VIA/II input point 1 setting
VIA/II input point 1 frequency
VIA/II input point 2 setting
VIA/II input point 2 frequency
VIB input point 1 setting
Frequency UP response time
VIB input point 1 frequency
Frequency UP step width
VIB input point 2 setting
Frequency DOWN response time
VIB input point 2 frequency
Frequency DOWN step width
Note1) Setting value of
Note2)
~
Note3) Don't set the same value between point 1 and point 2.
If set the same value, the
Function
0 ∼ 100 (%)
0.0 ∼ 400.0 (Hz)
0 ∼ 100 (%)
0.0 ∼ 400.0 (Hz)
0 ∼ 100 (%)
0 ∼ 100 (1: 0.1 s)
0.0 ∼ 400.0 (Hz)
0.0 ∼ 400.0
0 ∼ 100 (%)
0 ∼ 100 (1: 0.1 s)
0.0 ∼ 400.0 (Hz)
0.0 ∼ 400.0
and
depending on the end of Type form. AN, WN : 60Hz, WP: 50Hz.
can be used as UP/DOWN function depend on the setting.
is displayed.
F-13
Adjustment range
Default setting
E6580757
6
0
0.0
100
50 or 60 *1
0
0
0.0
0
100
100
50 or 60 *1
50 or 60 *1