5.9

Maximum frequency

• Function
1) Programs the range of frequencies output by the inverter (maximum output values).
2) This frequency is used as the reference for acceleration/deceleration time.
5
If
Parameter setting
Title

5.10 Upper limit and lower limit frequencies

• Function
Programs the lower limit frequency that determines the lower limit of the output frequency and the upper
limit frequency that determines the upper limit of that frequency.
Short across the R-CC terminals: reverse rotation
* Reverse rotation is valid if short across the F-CC terminals and R-CC terminals at the same time.
This function is valid only when
: Maximum frequency
Output frequency
(Hz)
is increased, adjust the upper limit frequency
Function
Maximum frequency
: Upper limit frequency
: Lower limit frequency
is set to 1 (operation panel).
When
• This function determines the
When
maximum value in line with the
ratings of the motor and load.
• Maximum frequency cannot be
adjusted during operation. To
adjust, first stop the inverter.
Frequency setting signal (%)
as necessary.
Adjustment range
30.0 ∼ 400 (Hz)
E-12
E6580757
Default setting
80.0