[D] Controls And Adjustments - Hoshizaki KML "F" SERIES Service Manual

Kml “f” series, kml “h” series modular crescent cuber
Table of Contents

Advertisement

[d] CONTROLS AND ADJUSTMENTS

The Dip Switch is factory-adjusted to the following positions:
FOR MODELS WITH THERMOSTAT:
DIP SWITCH NO.
KML-250 MAH
KML-250 MWH
350M_F, 350M_H
KML-450M_F, M_H
KML-600MAF, MAH
KML-600MWF, MWH
KML-600MRF, MRH
FOR MODELS WITH MECHANICAL BIN CONTROL:
DIP SWITCH NO.
KML-250 MAH
KML-250 MWH
350M_F, 350M_H
KML-450M_F, M_H
KML-600MAF, MAH
KML-600MWF, MWH
KML-600MRF, MRH
Switch Nos. 1 and 2:
Used for adjustment of the Defrost Timer.
The Defrost Timer starts counting when the Thermistor reads a certain temperature
at the Evaporator outlet.
Switch Nos. 3 and 4:
Used for adjustment of the Drain Timer.
When a freeze cycle is completed, the Pump Motor stops, and the icemaker
resumes operation in 2 seconds. Then the Pump Motor drains the Water Tank
for the time determined by the Drain Timer. The Drain Timer also determines the
time to restrain completion of a defrost cycle, i.e. the minimum defrost time.
Switch Nos. 5 and 6:
Used for adjustment of the Drain Counter.
The Pump Motor drains the Water Tank at the frequency determined by the Drain
Counter.
1
2
3
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
ON
OFF OFF
1
2
3
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
ON
OFF OFF
4
5
6
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
4
5
6
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
39
7
8
9
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
7
8
9
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
10
OFF
ON
ON
ON
ON
10
OFF
ON
ON
ON
ON