[c] CONTROLS AND ADJUSTMENTS

a) Default Dip Switch Settings
The dip switch is factory-adjusted to the following positions:
S1 Dip Switch No.
KMD-210AB-HC
S2 Dip Switch No.
KMD-210AB-HC
Do not adjust the S2 dip switch. These must be left in the factory default position, or the unit
will not operate properly.
b) Harvest Timer (S1 dip switch 1 & 2)
Used for adjustment of the harvest timer. The harvest timer starts counting when the
thermistor reads a certain temperature at the evaporator outlet.
Dip Switch Setting
No. 1
No. 2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
1
2
3
OFF
OFF
OFF
1
2
3
ON
OFF OFF OFF
Time (seconds)
60
90
120
180
4
5
6
OFF
ON
ON
* Functions of S2 dip switch nos. 2
through 6 depend on program version.
4
5
6
ON
OFF
10
7
8
9
ON
ON
OFF
S2 Dip Switch
10
OFF