Panasonic PT-60LCX64-K Service Manual page 30

Multi media display
Hide thumbs Also See for PT-60LCX64-K:
Table of Contents

Advertisement

PT-60LCX64-K
POWER C.B.A. CHECK
It is possible to check the Power C.B.A. only with no load.
jumper wire
Power C.B.A. (Component Side)
Refer to "CHECKING THE POWER C.B.A." in "TROUBLESHOOTING HINTS FOR COMPONENT LEVEL REPAIR."
Note:
To turn on the relay (RL801), connect a jumper between TP810 and TP1015 by soldering. Then, plug in AC Cord (snap sound).
After servicing the Power C.B.A., be sure to connect the Connector P1006 on the Power C.B.A. to install the Fan 4.
DIGITAL TUNER POWER C.B.A. CHECK
It is possible to check the Digital Tuner Power C.B.A. only with no load.
Refer to "CHECKING THE DIGITAL TUNER POWER C.B.A." in "TROUBLESHOOTING HINTS FOR COMPONENT LEVEL REPAIR."
TP810
No connection
TP1015
RL801
AC Cord
To AC outlet
No connection
Relay:
RL801
Fig. S1-4
Note:
P1201
Digital Tuner Power C.B.A.
No connection
Fig. S1-5
30
AC Cord
No connection
<Power C.B.A.>
No connection