7. External fitting

A. Disassembly

(1) Cabinet disassembly 1
1) Open the front cabinet.
2) Remove the front cabinet band. Pull out the slide pin (B), and
remove the front cabinet (C).
B
A
(2) Cabinet disassembly 2
1) Remove the front cabinet.
2) Open the left cabinet. Remove the screw and remove the front
frame cover.
(3) Cabinet disassembly 3
1) Remove the screw, and slide the paper exit tray cabinet right
to the right to remove.
(4) Cabinet disassembly 4
1) Remove the screw, and remove the rear cabinet (A). Remove
B
A
C
(5) Cabinet disassembly 5
1) Remove the manual paper feed unit.
2) Pull out the cassette and the knob.
3) Open the front cabinet.
4) Remove the screw.
5) Lift the cabinet, and slide and remove the front right cabinet
AR-BC320 DESCRIPTIONS OF EACH SECTION 7 - 42
the screw, and remove the DC power CFM unit (B) and the
connector. Remove the screw, and remove the ROM cover
(C) and the rear connection cabinet (D).
When assembling, insert the boss in section E into the hole
in the frame.
B
E
(A) upward.
D
C
A
A