of heavy winds may require the placement of a barrier for protection. The air inlet,
in normal weather conditions, should face the prevailing wind direction.
3.
Locate the Generator on a concrete slab or other area where rain drainage or flood
waters can not reach it.
4.
Generator placement should allow four feet of access to all sides for maintenance
and proper air cooling.
5.
Place the Generator as close as possible to the electrical tools and equipment
being powered to reduce the length of extension cords.
6.
To ground the Generator, connect a #6 AWG grounding wire (not included) from
the Grounding Terminal (9) on the Control Panel to a grounding rod (not included)
that has been driven at least 24 inches deep into the earth. The grounding rod
must be an earth-driven copper or brass rod (electrode) which can adequately
ground the Generator. (see Figure c.)
1.
IMpoRTANT: Your warranty is voided if you do not put engine oil in the
Engine's crankcase prior to its first use. Before each use, check the oil level.
Never run the Engine with low or no engine oil. Running the Engine with no or low
engine oil WILL permanently damage the Engine.
2.
The Engine MUST be filled with a high quality engine oil. If the Engine will be
run in temperatures above 32 degrees Fahrenheit, use sAE 30 weight oil. If the
Engine will be run in temperatures below 32 degrees Fahrenheit, use sAE 5w-30
weight oil.
SKU 66603
For technical questions, please call 1-800-444-3353.
coNcRETE slAb
pRE-sTART INsTRUcTIoNs
FIGURE c
GRoUNDING TERMINAl (9)
#6 AwG GRoUNDING wIRE
(NoT INclUDED)
GRoUNDING RoD
(NoT INclUDED)