T7200D,E SERIES 2000 COMMERCIAL MICROELECTRONIC THERMOSTATS
Installer Setup
Number
(Press
Unoccupied
Temp key
to change)
Select
Minimum off-
38
times in heating.
Installer Setup
40
lockout (keypad
lockout is
enabled and
disabled by dip
switch 1 on back
of thermostat).
IMPORTANT
Review the settings to confirm that they match
the system. Press Run Program to exit the
Installer Setup. Set the current day and time
immediately.

Setting Current Day and Time

1. Press Set Current Day/Time.
NOTE: On initial power up or after an extended
power loss, 1:00 pm flashes on the LCD
until a key is pressed.
Set Current
Day/Time
Set Program
Run
Occupied
Unoccupied
Program
Start Time
Start Time
Temporary
Set Current
Clear
Occupied
Day/Time
Start Time
Continous
Unoccupied
2. Press Day until the current day is displayed.
NOTE: Sun=Sunday, Mon=Monday,
Tue=Tuesday, Wed=Wednesday,
Thu=Thursday, Fri=Friday, Sat=Saturday.
Day
Set Program
Run
Occupied
Unoccupied
Program
Start Time
Start Time
Temporary
Set Current
Clear
Occupied
Day/Time
Start Time
Continous
Unoccupied
3. Press increase
time is displayed.
NOTE: Tapping the Set Current Day/Time changes
the time in one hour increments.
Set Program
Run
Occupied
Unoccupied
Program
Start Time
Start Time
Temporary
Set Current
Clear
Occupied
Day/Time
Start Time
Continous
Unoccupied
62-0128—2
Table 2. Thermostat Installer Setup Options (Continued).
Factory Setting
Display
4
4—4-minute
0
0—No Installer Setup
Set Day/Time
PM
Set Temperature
Change
Time/Temp
Occupied
Unoccupied
Day
Temp
Temp
Mon
Heat/Cool
Copy
Settings
System
Fan
Set Day/Time
PM
Set Temperature
Change
Time/Temp
Occupied
Unoccupied
Day
Temp
Temp
Tue
Heat/Cool
Copy
Settings
System
Fan
or decrease
until the current
Set Day/Time
PM
Set Temperature
Change
Time/Temp
Occupied
Unoccupied
Day
Temp
Temp
Tue
Heat/Cool
Copy
Settings
System
Fan
Description
Display
0, 1, 2, 3,
minimum off-time.
or 5
1
lockout.
4. Press Run Program.
Program

INSTALLER SYSTEM TEST

Use the Installer System Test to check the thermostat
configurations and operation. Refer to Table 3 for a list of
the available system tests.
Table 3. Tests Available in Installer System Test.
Test
Number
M4951B
10 to 19
30 to 39
40 to 49
60 0 to
60 19
70 to 79
M4952B
To start the system test:
CAUTION
Possible Equipment Damage.
Equipment damage can result if compressor is
cycled too quickly.
The minimum off-time for compressors is bypassed
during the Installer System Test.
Press and hold the increase
M4953B
the same time, until 10 appears. All segments of the LCD
are displayed for three seconds before 10 appears. See
Fig. 10 and 11.
6
Other Choices
(Press
or
key to change)
Description
Minimum number of minutes
(0 thru 5) the heating
equipment will be off
between calls for heat.
1—Installer Setup lockout
activated.
Run
Set Program
Set Temperature
Change
Time/Temp
Run
Occupied
Unoccupied
Occupied
Unoccupied
Program
Start Time
Start Time
Day
Temp
Temp
Temporary
Set Current
Clear
Heat/Cool
Occupied
Day/Time
Start Time
Copy
Settings
Continous
Unoccupied
System
Fan
System Test Description
Heating equipment can be turned on and
off
Cooling equipment can be turned on and
off
Fan equipment can be turned on and off
Keyboard keys test
Thermostat information including date
code, software versions and subbase
identification are displayed
and decrease
Actual
Setting
AM
Room
Mon
Occupied 1
System
Fan
Auto
Heat
M4954A
keys, at

Advertisement

Table of Contents
loading