LG KG195 Service Manual page 82

Lg kg195 mobile phone service manual
Hide thumbs Also See for KG195:
Table of Contents

Advertisement

Test item
MODE
Start up
E-GSM
Call setup
E-GSM
TX Power
E-GSM
DCS1800
RMS Phase error
E-GSM
DCS1800
PEAK Phase error
E-GSM
DCS1800
Frequency Error
E-GSM
DCS1800
Power Vs Time
E-GSM
DCS1800
RX Class2 RBER
E-GSM
DCS1800
RX Level
E-GSM
DCS1800
RX Quality
E-GSM
DCS1800
Hand over
E-GSM to
DCS1800
*1 Refer to 1.Overview Channel selection condition
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Procedure
1. Set SIM card and dummy battery to HHP
2. Power on HHP
3. Wait to indicate "GSM Test Net 001"
1. Input the PTE command "StartCall"
2. Input the PTE command "Receivecall".
3. Wait to indicate "Active" to establish call
1. ARFCN is assign to Mch ( and Lch/Hch )
2. Set PL to 5(E-GSM) or 0(DCS1800)
3. Wait to establish hand over
4. Measure output power
1. ARFCN is assigned to Mch ( or Lch/Hch )
2. Set PL to 5(E-GSM) or 0(DCS1800)
3. Wait to establish hand over
4. Change mode of GSM tester to "Phase/FREQ"
5. Set analyze burst number to 50
6. Read "RMS maximum" window
1. ARFCN is assigned to Mch ( or Lch/Hch )
2. Set PL to 5(E-GSM) or 0(DCS1800)
3. Wait to establish hand over
4. Change mode of GSM tester to "Phase/FREQ"
5. Set analyze burst number to 50
6. Read "PEAK maximum" window
1. ARFCN is assigned to Mch ( or Lch/Hch )
2. Set PL to 5(E-GSM) or 0(DCS1800)
3. Wait to establish hand over
4. Change mode of GSM tester to "Phase/FREQ"
5. Set analyze burst number to 50
6. Read "Frequency error maximum" window
1. ARFCN is assigned to Mch
2. Set PL to 5(E-GSM) or 0(DCS1800)
3. Wait to establish hand over
4. Change mode of GSM tester to "Power Ramp"
5. To check pass/fail indication under three mode "TOP
2dB" "Rise edge" and "Fall edge"
1. ARFCN is assigned to Mch*1
2. Set PL to 5(E-GSM) or 0(DCS1800)
3. Wait to establish hand over
4. Change mode of GSM tester to "Bit error"
5. To define sampling value to 10000
6. To define measure "Res Type 2"
7. To adjust base station output level to -103.5dBm
8. Wait to indicate BE Ratio and read it.
1. Same setting and procedure as RX RBER
2. Wait to indicate "Mobile reported Rxlev" and read it.
1. Same setting and procedure as RX RBER
2. Wait to indicate "Mobile reported RX Qual" and read it.
1. Change mode of GSM tester to "DUAL BAND"
2. To define DCS1800 parameter. ARFCN to Mch, Base
station output level to -85dBm, Mobile power level to PL0.
3. Push "Execute" and check establish hand over.
- 81 -
6. Repairing
LGE Internal Use Only

Advertisement

Table of Contents
loading