Planning Your Schedule; Setting Your Program Times - Robertshaw 300 Installation & Programming Manual

Deluxe programmable thermostats
Hide thumbs Also See for 300:
Table of Contents

Advertisement

q
I
OnI
4lMln.bTaxa)
z-ONI
w-
w-
I
I
OFF ON
q
2 minute (min. on)
4 minute. (min. on)
Keypad Locked
Keypad unlocked
DAY/TIME
iElTIN(
THE CURRENT
I
Press the CLOCK button.* The display will flash a day of the week.
Press the@ or@ buttons until the current day shows.
Press the CLOCK button again. The display will flash the hour. (Note the
AM/PM indicator).
Press the@ or@ buttons until the current hour shows.
Press the CLOCK button again. The display will flash the minutes.
Press the@ or@ buttons until the current minutes show.
Press the CLOCK button and the current day and time are now set.
* Note: If a button is not pushed in 15 seconds, the thermostat will automatically return
to normal operation.
SElTlNG YOUR PROGRAM TEMPERATURES
With your specific program determined, you are ready to begin programming. You will now
enter the individual program period temperatures
Press the MODE button until
I 1
Press the SET TEMP button.' The first program period (Morning) will be displayed.
Press the@o@buttons to adjust that program periods desired temperature for heating.
Repeat Steps 2 & 3 for the Day, Evening and Night program periods. Remember, If your
thermostat was set-up for 2 program periods, you will only have to repeat Steps 2 & 3 for
the Night program period.
5
Press the MODE button until COOL is displayed. You will now enter the individual
program period temperatures for the cooling program.
6.
Repeat Steps 2, 3 & 4 for the cooling temperatures.
7 .
Press the MODE button until your desired mode of operation appears: HEAT-AUTO-OFF-COOL.
';8
Press the RESUME button to return to normal operation.
Note: If a button
not pushed in 15 seconds, the thermostat wi l l automatically return to normal operation. You may easily go
IS
l
back rnto the programmlng portion simply by repeatedly pressing the SET TEMP button
. . ..__.._.... . . 24VAC supply from cooling
equipment transformer
Energizes the cooling equipment with a
Y . ..." . . . . . uI . . . . _.
call for
cooling
. . . . . . . . . . . . . . . . . . . .
G
Fan is energized with a call for Cooling of
selected by pressing the Fan button
RB2 . . . . . . . . . ..__.. Use to connect Outdoor Temperature
RSl
Sensor and/or Indoor Remote Sensor
RSl
Options. Refer to the instructions
included with the sensors.
Equipment load resistors(proivided) may be required
on the Y and G switching circuits if the equipment
loads do not draw .080 amps per circuit minimum.
Connect load resistors at the equipment.
24
for the heating program.
HEAT is displayed.
until you get back
where you left off
to
26
PLANNING YOUR SCHEDULE (30&225,300-227,3OO-229)
Your new Robertshaw programmable thermostat has been designed so that you can seledt
either 2 program periods (Day or Night) or 4 program periods (Morning, Day, Evening or Night;
The thermostat comes from the factory set for
please refer to the "2 Events or 4 Events Per Day" section on page 8.
To help save programming time, we suggest you use the worksheet below to set-up your
specific program.
Note: If you plan to use the Automatic Changeover Mode, you can not set your heating and
cooling temperatures closer than 2 degrees
Programming Chart
PROGRAM PERIOD
MORNING &
I
HEAT
TEMPERATURES
COOL:
(TIME)
Monday
Tuesday
Wednesday
Thursdav
Friday
Saturday
1 Sunday
I
I

SETTING YOUR PROGRAM TIMES

Referring to your Schedule Planner, you will now enter the times for the program periods.
1. Press the PROGRAM button. The display will flash a day of the week.
1
2. Press the@ or@ buttons to select the day you wish to program. (We suggest
/
starting with Monday)
I
:
72
'
3. Press the PROGRAM button. The display will flash the hour of the first period
,
(Morning). (Note the AM/PM indicator).
&I
Press the@or@ buttons to adjust the desired hour for the first program period.
Press the PROGRAM button again. The display WIII flash the minutes.
Press the@or@buttons to adjust the desired minutes for the first period. (Note
the minutes are in Increments of 10).
Repeat Steps 3-6 for the Day, Evening and Night periods. Remember, if your
thermostat was set-up for 2 program periods, you will only have to repeat Steps
3-6 for the Night period.
After entering the Night period, press the PROGRAM button. "COPY" will be
- 8.
displayed. The COPY function will allow program times to be copied to sequential
days. If you do not wish to copy the program times to another day (or block of
days), proceed to Step 11
9.
Press theaor@ buttons to select the next individual day, or block of days, to
copy the program times to.
lO.Press the PROGRAM button to copy the program times to the selected days of the week.
1 l.Repeat Steps l-10 for any remaining unprogrammed days of the week.
i
12.When finished, you can verify that all program periods are programmed correctly
by repeated pressing the PROGRAM button. When "COPY" appears, press the
PROGRAM button to skip to the next day.
Note: If a button is not pushed in 15 seconds, the thermostat will automatically return to normal operation. You
l
may easily go back into the programming portion simply by repeatedly pressing the PROGRAM button until you
get back to where you left off.
4
program periods. To change this setting,
for the same program period.
apart
DAY <o:
EVENING E
NIGHT
HEAT:
HEAT
HEAT:
COOL.
COOL:
COOL:
(TIME)
(TIME)
I
I
I
25
3 7
(TIME)
-1

Advertisement

Table of Contents
loading