STR-DA7100ES
NOTE WHEN INSTALLING THE ILINK BOARD
– BOTTOM VIEW –
NOTE: Assemble it after CONECT board is removed from MOTHER COM board once, and it connects it with ILINK board
when you remove ILINK board from the set for some repairs.
The purpose of this is to prevent the bad connection of the connector of CONECT board (CNP301, CNP302)
and ILINK board (CN3003, CN3004).
1 Remove the CONECT board
CONECT board
(CNR207, CNR208)
Bend of Capacitors
NOTE: Before assembling the ILINK board. bend each capacitor so that capacitors should not come in contact
with the mother board.
10
from the MOTHER COM board.
MOTHER COM board
(CN5207, CN5208)
capacitor
2 Connect the CONECT board (CNP301, CNP302)
to the ILINK board (CN3003, CN3004).
3 Connect the CONECT board (CNR207, CNR208)
to the MOTHER COM board (CN5207, CN5208).
ILINK board
CONECT board
(CNP301, CNP302)
ILINK board
(CN3003, CN3004)