Notes - Siemens SATURN IIE EPABX Installation Test Procedures

Epabx
Table of Contents

Advertisement

.
SATURN IIE EPABX
Installation Test Procedures
NOTES: 1) If the system
test is classmarked with TSTAPP feature, the maintenance test phone is not required to enable
Apparatus Diagnostic routines; therefore, perform only steps 5 through 9.
2) If the system option flag TSTDIAG has been disabled in the data base or the Siemens Digital Telephone under
test is not classmarked with the TSTAPP feature, the maintenance test phone is required to enable or disable
the Apparatus Diagnostic routines; therefore, perform the entire procedure (steps 1 through 10).
PROCEDURE
1
Place
maintenance
off-hook.
D i a l t h e D i a g n o s t i c T e s t A c c e s s C o d e .
2
3
Dial 3 to enable the Apparatus Diag-
nostic test.
4
P l a c e m a i n t e n a n c e t e s t p h o n e N o n e .
on-hcok.
P l a c e t h e S i e m e n s D i g i t a l T e l e p h o n e
5
under test off-hook.
G
Dial the Siemens Digital Telephone
test access code.
7
Depress any button in the Siemens
D i g i t a l T e l e p h o n e u n d e r t e s t t o i n i t i a t e
test.
(Note: The display test can be sus-
pended any time by depressing any
button. The test can be resumed at
any time in the same manner.)
8
P l a c e S i e m e n s D i g i t a l T e l e p h o n e
hook to terminate test or wait 30 se-
conds for test timeout.
If no additional Apparatus Diagnostic
9
T e s t s a r e t o b e p e r f o r m e d , p r o c e e d a s
follows:
Place
maintenance
off-hook.
D i a l t h e D i a g n o s t i c T e s t A c c e s s C o d e .
Recall dial tone returned.
Dial 2 to disable the Apparatus Diag-
nostic Test.
P l a c e m a i n t e n a n c e t e s t p h o n e N o n e .
on-hook.
G-24
Table 6.09 Siemens Digital Telephone -DYAD Display Test
flag TSTDIAG has been enabled in the data base or the Siemens Digital Telephone under
VERIFICATION
test
phone
Dial
tone
is
returned.
Recall dial tone is returned.
Confirmation tone is returned.
Dial tone returned.
Recall dial tone is returned. The Ac-
then the display unit clears.
Groups of 16 of each of the displaya-
ble characters are scrolled in the se-
last characier
played the following occurs:
All button LEDs flash and the audible
alerting device sounds at intervals.
TEST COMPLETE is displayed.
test
phone
Dial
tone
returned.
Recall dial tone is returned
N o n e .
IS NOT OBTAINED
If reorder tone is returned, the Sie-
mens Digital Telephone Display Test
is being used, retry later.
If verification is not obtained, either
t h e S i e m e n s D i g i t a l T e l e p h o n e o r t h e
SLMD circuit is defective. Replace
(underscore) is dis-
Siemens Digital Telephone with a
good one and retry test. If verification
is obtained, replace the Siemens Dig-
T e l e p h o n e .
If verification is still not obtained,
replace the SLMD PCS.
Issue 1, May 1986
or disabie the
IF VERIFICATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saturn iie

Table of Contents