Notes - Siemens SATURN IIE EPABX Installation Test Procedures

Epabx
Table of Contents

Advertisement

SATURN IIE EPABX
Installation Test Procedures
Table 6.06
NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the Siemens Digital Telephone under
test is classmarked with TSTAPP feature, the maintenance test phone is 'not required to enable or disable the
Apparatus Diagnostic routines; therefore, perform only steps'5 through 9.
2) If the system option flag TSTDIAG has been disabled in the data base or the Siemens Digital Telephone under
test is not classmarked with the TSTAPP feature, the maintenance test phone is required to enab!e
the Apparatus Diagnostic routines; therefore, perfcrm ihe entire procedure (steps 1 through i0).
PROCEDURE
1
Place the maintenance test phone
off-hook.
2
D i a l t h e Diagncstic Test Access Code.
3
Dial 3 to enable the Apparatus Diag-
nostic Tests,
4
P l a c e m a i n t e n a n c e t e s t p h o n e N o n e .
on-hook.
5
Place JR-DYAD Telephone off-hook.
6
Dial the Siemens Digital Telephone
Test Access Code.
7
Depress the Siemens JR-DYAD Tele-
phone keypad buttons as, follows: 1,
2, 3, 4, 5, 6, 7, 8, 9, 0, * , #.
8
Depress the JR-DYAD feature buttons
i n t h e s e q u e n c e s h o w n i n F i g u r e 6 . 2 1 .
9
Place Siemens JR-DYAD Telephone
under test on-hook to terminate test.
1 0
If no additional Apparatus Diagnostic
T e s t r o u t i n e s a r e t o b e p e r f o r m e d , p r o -
ceed as follows:
Dial the Diagnostic Test Access code.
Dial 2 to disable the Apparatus Diag-
nostic Test.
P l a c e m a i n t e n a n c e t e s t p h o n e N o n e .
on-hook.
Siemcns Digital Telephone - JR-DYAD Button Test
VERIFICATION
Dial tone is returned.
Recall dial tone is returned.
Confirmation tone is returned.
Dial tone is rereturned.
Recall dial tone is returned.
Button LEDs light when depressed
and extinguish when the next button
is depressed.
After the last button is depressed, the
following indications occur:
tone is returned.
All button LEDs flash.
T h e a u d i b l e a l e r t i n g d e v i c e s o u n d s a t
intervals.
Siemens JR-DYAD Telephone returns
to normal operation.
test phone Dial tone is returned.
Recall dial tone is reiurned.
N o n e .
Issue 1, May 1986
or disable
IF VERIFICATION
IS NOT OBTAINED
If reorder tone is returned, the Sie-
m e n s J R - D Y A D Telephcne
B u t t o n T e s t
is in use, try later.
Ii proper verification is net obtainsd or
busy tone is returned at any iime,
either the keypad buttons or feature
buttons were depressed out of se-
the JR-DYAD Telephone is
defective, or the SLMD circuit is
defective. To isolate the failure, retry
test to verify that the buttons were not
depressed out of sequence.
I f p r o p e r v e r i f i c a t i o n i s n o t o b t a i n e d o r
busy tone is returned again, replace
t h e S i e m e n s J R - D Y A D T e l e p h o n e u n -
der test with a known good JR-DYAD
Telephone and retry test. If proper
verification is not obtained or busy
tone is returned again, the SLMD cir-
cuit is defective and the S L M D PC6
requires replacement.

Advertisement