Notes - Siemens SATURN IIE EPABX Installation Test Procedures

Epabx
Table of Contents

Advertisement

SATURN IIE EPABX
Installation Test Procedures
S T E P
7
Place station under test on-hook.
8
Pick up handset to answer test tail.
9
Verify that the test tone level is cor-
1 0
Place station under test on-hoo!(.
1 1
I f n o a d d i t i o n a l T e s t r o u t i n e s a r e t o b e
performed, proceed as follows:
Place maintenance test phone Dial tone is returned.
Dial the Diagnostic Test Access Code
Dial 2 to disable test routine.
Place maintenance phone on-hook.
NOTES: 1) If the system option flag TSTDIAG has been enabled in the data base or the station under test is classmaiked
with the TSTAPP feature, the maintenance test phone is not required to enable or disable the Apparatus Test
routines; therefore, perform only sieps 5 through 8.
2) If the system option flag TSTDIAG has been disabled in the data base or the station under test is not classmarked
with the TSTAPP feature, the maintenance test phone is required to enable or disable the Apparatus Test rou-
tines; therefore, perform the entire procedure (steps 1 through 9).
S T E P
PROCEDURE
1
Place maintenance test phone Dial tone is returned.
off-hook.
2
D i a l t h e D i a g n o s t i c T e s t A c c e s s C o d e .
3
Dial 3 to enable the tests.
4
P l a c e m a i n t e n a n c e t e s t p h o n e N o n e .
on-hook.
5
Place DTMF station under test Dial tone returned.
off-hook.
6
D i a l t h e T e s t D T M F P a d A c c e s s C o d e .
Station Line Test
Ringing returned.
Test tone (1004Hz
returned.
N o n e .
Recall dial done is returned,
N o n e .
N o n e .
6.04 DTMF Fad Test
VERIFICATION
Recall dial tone is returned.
Confirmation tone returned.
Recall dial tone is returned.
Issue 1, May 1986
IS NOT OBTAINED
If ringing is not heard, switch the sta-
tion instrument to determine if it is
defective. If ringing is still not heard,
replace the associated subscriber line
P C B .
If the returned test tone level is weak,
swap the instrument to determine if it
is defective If the test tone level in-
creases considerably, replace the s:a-
tion instrument. If test tone level
remains weak, replace the associat-
ed
subscriber
line
PCB
(SLMA,
or SLMD).
IF VERIFICATION
IS NOT OBTAINED
.