CD SECTION
Note:
1.
CD Block is basically constructed to operate without
adjustment. Therefore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10 M impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
5.
Adjust the focus bias adjustment when optical block is replaced.
Focus Bias Check
BD board
TP (RF)
TP (VC)
Procedure :
1.
Connect oscilloscope to TP (RF) and TP (GND) on CD board.
2.
Turned Power switch on.
3.
Put disc (YEDS-18) in and press the
back.
4.
Confirm that oscilloscope waveform is as shown in the figure
below. (eye pattern)
A good eye pattern means that the diamond shape ( ) in the
center of the waveform can be clearly distinguished.
Adjustment Location:
– CD BOARD (Conductor Side) –
TP (GND)
oscilloscope
(DC range)
+
[CD
]
u
button to play-
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.2
0.1 Vp-p
IC701
TP (RF)
IC703