How to Re-calibrate the SE-2800 T-Bar

After a firmware update of the switcher it will be necessary to re-calibrate the T-Bar to get it working correctly.
Move the T-Bar to its lowest position.
1.
Power OFF the SE-2800 switcher.
2.
Press and hold down button 1 on both the Program and Preset
3.
rows of the switcher's keyboard.
4.
Power ON the SE-2800 switcher while still holding down the
buttons in step 3.
5.
The switcher will start but the keyboard lights will remain dead except
for the T-Bar progress LEDs. When these LEDs flash ON and OFF
release the buttons from step 3.
6.
Move the T-Bar to its highest position and then press the CUT
button.
Move the T-Bar back to its lowest position and then press the
7.
AUTO TAKE button.
To exit the calibration procedure press the CLOCK button.
8.
Ensure the TIMER button is OFF.
9.
10. Test the T-Bar.