Early Ambush - Bosch D9412GV4 Owner's Manual

Control panels
Table of Contents

Advertisement

196 en | Options
31.2

Early Ambush

When the Early ambush feature is enabled, the security
system, requires two passcodes to turn off the area.
Entering the first passcode turns the area off and begins
counting down Early Ambush Time (__ minutes). A user
must enter the second passcode before Early Ambush
time expires. Early Ambush is disabled for SIA compliant
systems.
If Early Ambush time expires before a user enters the
second passcode, the system reports to you security
company that the system was disarmed under duress.
You can enter the first passcode a second time as the
second passcode.
You can enter the passcodes at the same keypad, or at
different keypads (if keypads are assigned to the same
area).
Early Ambush is:
2014.04 | 05 | F.01U.287.176
enabled on my system.
disabled on my system.
Control Panels
Bosch Security Systems, Inc.