Why Trane Controls?
Whether involved in a retrofit or in new construction applications, Trane has the control design to fit the sys-
tems requirements. The broad range of control packages offered range from a field convertible end-device
package, to a complete building automation system solution by incorporating the ICS (Integrated Comfort
system) design.
The good news is...Trane ICS controls (both ZN520 and TUC), are factory tested and commissioned with Trane
application expertise to provide comfort, efficiency, and reliability, as well as, single-source warranty and ser-
vice. With Tranes integrated controls, the installed costs are lower because the equipment has turn-key factory
controls and every component of the system is optimized to fit with the controller. Trane installs not only the
controller, but also the hardware that works intimately with the controller to allow the system to function prop-
erly (i.e., piping package, valves, dampers, actuators, etc.). When a classroom unit ventilator with Trane con-
trols arrives to the jobsite, it is completely ready for quick installation and operation.
The following chart explains the difference in the control design.
GRAPHIC
No Controls/Field
Unit comes equipped with an auto transformer,
Installed
fan speed switch and a damper blade only.
End-Device
Package
(EDP)
TM
Tracer ZN520
TUC
Pneumatic
UV-PRC001-EN

Controls

DESCRIPTION
In a retrofit market where a
non Trane controller has
been applied to the building.
A pre-wired (to a termi-
Retrofit market where single
nal strip) control offer-
and multiple unit replace-
ing of selected control
ment occurs.
components. The EDP is
ready for a field pro-
New building design where
vided controller and
field provided controls are
temperature sensor.
specified.
Direct Digital Control
Retrofit market where overall
board designed to pro-
system upgrade is specified.
vide control of the
HVAC equipment, as
Multi-unit (
well as total building
where units are linked by a
management.
common twisted pair of wire
for a communication link.
Direct Digital Control
Retrofit market where a full
board used in an ICS
building management sys-
setting to combine
tem is specified.
HVAC and building
management into one
Multi-unit (
comfort system.
where units are linked to a
Tracer or Tracer Summit sys-
tem to provide complete
building management con-
trol.
The mechanical 24V
Retrofit market where exist-
pneumatic contoller
ing units or additions to cur-
provides a mixed air
rent pneumatic controls are
actuator, discharge air
specified.
sensor and required
solenoids and pneu-
matic switches.
APPLICATION
ICS
No
No
Yes
±100
) installation
Yes
±100
) installation
No
TM
PROTOCOL
WHERE TO FIND
Not Available
Not Available
Page 24
Comm5
Page 26
Comm4
Page 30
Not Available
Page 33
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vuv

Table of Contents