Download Print this page

Increasing The Lamp's Life - Chauvet Legend 300E Spot Quick Reference Manual

Hide thumbs Also See for Legend 300E Spot:

Advertisement

Legend 300E Spot QRG
Continued from previous page
MODE 1
Channel Function
(Cont.)
Color
8
(Cont.)
9
Cyan
10
Magenta
11
Yellow
12
Gobo 1
13
R-Gobo 1
14
Gobo 2
Continues on the next page
Value
Percent/Setting
064  127
Color Mix
128  189
Fast~Slow CW rotation
190  193
Stop
194  255
Slow~Fast CCW rotation
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  007
Open
008  014
Gobo 1
015  021
Gobo 2
022  028
Gobo 3
029  035
Gobo 4
036  042
Gobo 5
043  049
Gobo 6
050  057
Gobo 7
058  067
Gobo 1 Shaking
068  077
Gobo 2 Shaking
078  087
Gobo 3 Shaking
088  097
Gobo 4 Shaking
098  107
Gobo 5 Shaking
108  117
Gobo 6 Shaking
118  127
Gobo 7 Shaking
128  189
Fast~Slow CW rotation
190  193
Stop
194  255
Slow~Fast CCW rotation
000  127
Index
128  189
Fast~Slow CW rotation
190  193
Stop
194  255
Slow~Fast CCW rotation
000  005
Open
006  010
Gobo 8
011  015
Gobo 9
016  020
Gobo 10
021  026
Gobo 11
027  031
Gobo 12
032  036
Gobo 13
037  041
Gobo 14
042  047
Gobo 15
048  057
Gobo 8 Shaking
058  067
Gobo 9 Shaking
068  077
Gobo 10 Shaking
078  087
Gobo 11 Shaking
088  097
Gobo 12 Shaking
098  107
Gobo 13 Shaking
108  117
Gobo 14 Shaking
118  127
Gobo 15 Shaking
128  189
Fast~Slow CW rotation
190  193
Stop
194  255
Slow~Fast CCW rotation
Page 10
Replacing
1) Turn the fixture off and disconnect it from the power outlet.
the Lamp
2) Wait at least 15 minutes for the lamp to cool down.
3) Loosen the two screws on the lamp cover (marked "A" in the diagram).
4) Lift and rotate the lamp cover as per the diagram to expose the base of
the lamp.
5) Rotate the ceramic base of the lamp 90º counterclockwise.
6) Pull the lamp out by holding it from its base only.
7) Insert the new lamp and turn it 90º clockwise.
8) Reverse steps 3 and 4.
9) Use the adjustment screws (marked "B" in the diagram) to position the
lamp in the center of the reflector to obtain the best output.
Increasing the
ALWAYS turn the lamp off by using the DMX controller or the
Lamp's Life
fixture's control panel. Then wait at least five minutes before switching
off the fixture. This will keep the fans running to extract any remaining
heat from the fixture's head.
DO NOT power cycle the fixture unless it is necessary.
DO NOT touch the lamp without wearing gloves to avoid leaving
grease on the bulb or on the contacts that could reduce the lamp's life.
ALWAYS change the lamp when it has reached its recommended
lifespan to avoid the risk of lamp explosion.