Setup; Lamp - Chauvet Legend 6000X User Manual

575w
Table of Contents

Advertisement

S
ETUP

Lamp

You will need to install a lamp prior to the initial operation of the fixture. A HMI575 high intensity
discharge lamp is included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp
with alcohol and wipe it with a lint free cloth before installation.
L a mp I n s t a l l a t io n
1. Unscrew thumbscrews (S1) to
detach the top cover.
2. Unscrew screws (S2) to remove
lamp cover and expose lamp
compartment.
3. Move lamp reflector back as indicated by the arrow.
4. If installing a new lamp, loosen both screws on the
double ended lamp to allow for the lamp to slide into the
lamp socket slots. Lower lamp evenly.
5. If replacing a lamp, loosen both lamp screws
(S3) to relieve tension from lamp socket slots
so you can slide the lamp freely, upwards and
out of lamp socket. Raise lamp evenly to
remove.
6. Before you tighten the lamp end screws,
rotate the bulb until the nipple on the envelope
(N) of the bulb is facing upwards as illustrated.
7. If you are replacing the lamp, you may want to
log the fixture hours in order to track the lamps
use. Navigate to the {LPti} on the menu display to obtain this
information. (Page 9, Control Board Functions)
LEG-6000 User Manual
1
S2
S3
N
6
S1
1
2
3
5
6
5
Revision: 2007-03-06/09:06

Advertisement

Table of Contents
loading

This manual is also suitable for:

Leg-6000

Table of Contents