Operation/procedure
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When the [START] key is pressed, a print is made and the display
returns to the mode selection menu.
(Initial screen)
(Input screen)
Sim51-2 RESIST ADJ.
1:BYPASS
50
2:TRAY1
50
3:TRAY2
50
1/3
50
Display items
Content
Manual feed
1:BYPASS
1st cassette
2:TRAY1
2nd cassette
3:TRAY2
3rd cassette
4:TRAY3
4th cassette
5:TRAY4
Back print
6:DUPLEX
SPF front
7:SPF(SIDE1)
surface
SPF back
8:SPF(SIDE2)
surface
Setup of various copy conditions: Similar to the normal copy mode.
Use of [SPECIAL FUNCTION] key, [JOB STATUS] key, and [INTER-
RUPT] key is inhibited.
51-9
Purpose
Adjustment
Function
Used to adjust ON/OFF timing of the separation
(Purpose)
voltage.
Item
Adjustment
Operation/procedure
Used to adjust ON/OFF timing of the separation voltage.
(Initial screen)
(Input screen)
Sim51-9 SHV SETTING
Sim51-9 SHV SETTING
1:SHV ON
50
1:SHV ON
2:SHV OFF
50
1
[ 1- 99]
Display
Content
items
Separation voltage ON timing
1:SHV ON
* Transfer V2ON reference
(synchronized with the
adjustment value of 50)
2:SHV OFF Separation voltage OFF timing
* Transfer V2OFF reference
(synchronized with the
adjustment value of 50)
(Executing screen)
Setting
Default
Remark
range
1-99
50
Tray selection:
Manual feed
cassette is
specified.
1-99
50
Tray selection:
1st cassette is
specified.
1-99
50
Tray selection:
2nd cassette is
specified.
1-99
50
Tray selection:
3rd cassette is
specified.
1-99
50
Tray selection:
4th cassette is
specified.
1-99
50
Tray selection:
Made by user.
1-99
50
Tray selection:
Made by user.
Tray selection:
Made by user.
50
50
Setting
Default
range
25-90
50
50-90
75
AR-M208 SIMULATION 8 - 12
53
53-8
Purpose
Adjustment
Function
Used to adjust the mirror unit SPF scan position
(Purpose)
automatically.
For the SPF scan position auto adjustment, the mirror
unit is shifted to 11mm before the SPF glass cover
edge and is moved by self-boost, and images are
scanned in each step, and the position from the glass
cover edge is automatically detected.
[Adjustment value]
Default: 50
Adjustment unit 1 = about 0.127mm
Operation/procedure
Keep the OC cover open for execution of this test command.
If the adjustment is normally completed, the adjusted value is dis-
played and written into the EEPROM.
If the adjustment is abnormal, "ERR" is displayed and the value is not
written into the EEPROM.
For that which is not adjusted because of abnormality, "---" is dis-
played.
(Initial screen)
(Executing screen)
Sim53-8 SPF AUTO
Sim53-8 SPF AUTO
PRESS OK KEY
EXEC
"EXEC" is highlighted during execution.
(Normal end screen)
(Abnormal end display)
Sim53-8 SPF AUTO
Sim53-8 SPF AUTO
SPF STOP ADJ [ 47]
SPF STOP ADJ [ERR]
PRESS OK KEY
EXEC
PRESS OK KEY
64
64-1
Purpose
Operation test/check
Function
Self print
(Purpose)
Key input = 1
Self print is performed in the 2-by-4 mode (2-line print
and 4-line non-print).
Key input = 2
Grid print is performed. (1cm, 1-dot width WLT/A3 print
(A3 main scan, WLT sub scan))
Section
Printer
Item
Operation
Operation/procedure
Enter a figure with the 10-key.
[When key input = 1]
Self print is performed in the 2-by-4 mode
Since scanning is not performed, if a document is set on the SPF, the
START key is invalid.
* Duplex print is invalid.
[When key input = 2]
Grid print is performed. (1cm, 1-dot width WLT/A3 print (A3 main scan,
WLT sub scan))
If the IMC board is not installed, key input cannot be made.
* Duplex print is allowed.
Setting range: 1 to 99
EXEC