Configuring Alarm Notifications - Lorex LH140 Instruction Manual

Digital video surveillance recorder
Table of Contents

Advertisement

Configuring Alarm Notifications

Configure the settings for alarm devices (not included).
To configure alarm notifications:
1
Click the Remote Setting tab, and click Alarm>Alarm.
2
Configure the following:
• Alarm In: Select the channel that you wish to configure.
• Alarm Type: Select the alarm type N/O (normally open), N/C (normally closed), or select OFF.
• Buzzer: Select the "beep" duration when an event occurs.
• Latch Time: Select the desired latch time when an alarm triggers.
• Show Message: Select the checkbox so that the system displays a warning message during
an alarm recording.
• Send email: Select the checkbox for the system to send out email alerts during alarm
recording.
• Full Screen: Select the checkbox to enable the system to go into Full-screen View when an
alarm triggers.
• Alarm out: Select the checkbox to enable alarm out devices to activate.
• Enable Record: Select the checkbox to enable system recording when an alarm triggers.
• Post Recording: Select the desired post recording time after an alarm triggers.
• Record Channel: Select the channels that the system should record during an alarm trigger.
3
Click Save to apply your settings.