Error Code
DC Power Supply
One of the DC-DC converters on
Failure
the main board of the display has
failed.
FPGA Initialization
One of the FPGAs on the main
Failure
board did not start up correctly.
Calibration
The main board could not
EEPROM Failure
communicate with the calibration
EEPROM.
Planar UltraRes User Manual
Meaning
Error Codes in the UltraRes Control Software
Display Behavior and Solution
The display will not start up if this
occurs.
Solution: The main board needs to
be replaced.
There are two possible causes: one
of the FPGAs has corrupt code or is
damaged.
Solution: First check the FPGA
status LEDs on the main board. If
one is not blinking, that FPGA
didn't start up. The FPGA code may
need to be programmed again.
Solution: If reprogramming an
FPGA doesn't work, it is likely the
FPGA is damaged. If this is the case,
the main board needs to be
replaced.
It is likely that the calibration
EEPROM cable is disconnected.
Solution: Connect the EEPROM
cable.