A7" Malfunction Of Swing Flap Motor (M1S) - Daikin VRV III-S RXYMQ36 48PVJU Service Manual

R-410a heat pump 60hz
Table of Contents

Advertisement

SiUS34-907
A7
3.5
"
" Malfunction of Swing Flap Motor (M1S)
A7
Remote
Controller
Display
Applicable
FXFQ, FXHQ, FXAQ
Models
Method of
Utilizes ON/OFF of the limit switch when the motor turns
Malfunction
Detection
Malfunction
When ON/OFF of the micro-switch for positioning cannot be reversed even though the swing flap
Decision
motor is energized for a specified amount of time (about 30 seconds)
Conditions
 Defect of swing motor
Supposed
 Defect of connection cable (power supply and limit switch)
Causes
 Defect of airflow direction adjusting flap-cam
 Defect of indoor unit PCB
Troubleshooting
Troubleshooting by Indication on the Remote Controller
119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-410aVrv iii-s rxymq36-48pvju

Table of Contents