Panel Description; Front Panel - Icom MA-500TR Instruction Manual

Class b ais transponder
Hide thumbs Also See for MA-500TR:
Table of Contents

Advertisement

2

PANEL DESCRIPTION

■ Front panel

Function display (p. 4)
The angle brackets show common or special display op-
erations, as described
• <Common> shows the common operation.
• <In the plotter display> shows the plotter display opera-
tion.
• <In the target list display> shows the target list display
operation.
• <In the danger list display> shows the danger list dis-
play operation.
2
q w
e
Speaker
o
i
below:
q DISPLAY MODE KEY [DISP MODE]
<Common>
➥ Push to switch the display mode between the plotter,
target list and danger list. (pp. 4−6)
r
➥ While in the Menu mode, push to exit it, and return to
the plotter, target list or danger list display which was
w
selected before you entered the Menu mode.
e
w LEFT AND RIGHT KEYS [Ω]/[≈]
t
<Common>
y
While in the Menu item setting mode, push to select a
menu option. (pp. 31, 35)
u
<In the plotter display>
➥ Push [Ω] to sequentially select each AIS target icon far-
thest from your vessel (or waypoint, if it is set; see page
26 for setting detail). (p. 15)
➥ Push [≈] to sequentially select each AIS target icon
closest to your vessel (or waypoint, if it is set; see page
26 for setting detail). (p. 15)
• A target box will appear around the selected target or waypoint
icon.
<In the danger list display>
➥ Push [Ω] to sort the AIS target data by CPA (Closest
Point of Approach). (p. 17)
➥ Push [≈] to sort the AIS target data by TCPA (Time to
CPA). (p. 17)

Hide quick links:

Advertisement

Table of Contents
loading