4-1. TROUBLESHOOTING GUIDE

PROBLEM
Product not holding
temperature
Lights will not
turn on
Not all lights turn on
More detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com,
203

SECTION 4. TROUBLESHOOTING

CAUSE
• Product held too long
• Radiant heat too low
• Air heat too low
• Defective fuse
• Faulty light bulb
or 1-800-417-8405 or 1-937-456-8405.
CORRECTION
• Only hold product for recommended times
• Turn to a higher setting
• Turn to a higher setting
• Check fuse and replace if necessary
• Replace with recommended bulb