The North Star Fireplace will fit the framed opening width of
43-7/8" tall. The finished cavity depth must be no less than 24".
Framing must extend straight up all the way to the ceiling.
Figure 10A shows a typical framing (using 2 x 4 lumber) of the
fireplace, assuming combustible materials are used. All required
clearances to combustibles around the fireplace must be adhered
to. Any framing across the top of the fireplace must be above
the level of the top standoffs.
CLEARANCES!
A minimum 1" air clearance must be maintained at the back and sides
of the fireplace assembly.
Chimney sections at any level require a 2" minimum air space
clearance between the framing and chimney section.
WARNING!
Do not apply combustible finishing materials over
any part of the front of this fireplace or a structure
fire may result. The metal fireplace face may only
be covered with noncombustible materials such
as ceramic tile, brick, or stone. Do not cover or
block any cooling air slots.
3. Electrical Access and Wiring Diagram
NOTE: The manual override switch, rheostat speed
control and cover plate are supplied. You will need to
supply: 14-3 wire with ground; 14-2 wire with ground;
standard wall mount junction box; wire nuts.
1. Remove outside air cover plate on the bottom
right side of the fireplace.
2. Thread the 14-3 with ground wire through the
opening with the strain relief on the cover plate.
3. Match colors to wire harness, (red to red, white
to white, etc) and secure with wire nuts.
NOTE: Wiring for blowers must be done before
framed enclosure is completed. If using a
Heat Zone kit, it also must be installed before
enclosure is complete.
When planning your fireplace location, the chimney construction and necessary clearances must be considered. The fireplace
system and chimney components have been tested to provide flexibility in construction. The following figures are the minimum
distances from the base of the fireplace.
1. Min overall straight height
2. Min height with offset/return
3. Max height
4. Max chimney length between
an offset and return
480-1081
Match colors to wire
harness (red to red,
white to white, etc) and
secure with a wire nut
F. CHIMNEY REQUIREMENTS
13 ft.
5. Maximum distance between chimney stabilizers
14.5 ft.
6. Double offset/return minimum height
50 ft.
7. Maximum unsupported chimney length between the offset and return
8. Maximum straight unsupported chimney height above the fireplace
12 ft.
10
2"
43-7/8"
42"
24"
Figure 10A- Framing the Fireplace
14-3 w/ground
WHITE
RED
BLACK
Figure 10B- Fan Wiring Diagram
Position mantel
60" from base of
the fireplace
Standard wall mount with
Junction Box
14-2 w/ground
WIRE NUT
WHITE
GREEN
35 ft.
20 ft.
6 ft.
35 ft.
4-03