Clearances - Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36 Owner's Manual

Wood burning fireplace installation and operation
Table of Contents

Advertisement

B. Clearances
WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specifi ed in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
Figure 6.2
Storm Collar
Roof Flashing
(attic)
(insulation)
2 in. (51 mm) min.
Ceiling Firestop
48 in.
1219 mm
0 in.
to floor
Clearances to Combustible Materials
Note: Chimney air kit and 11-10 in./279-254 mm adapter are not shown,
but are required in Canada.
Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 11/08
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
Attic
Insulation
Shield
(ceiling)
Offset/Return (secured
with hanger straps)
(ceiling)
Must have 2 in. (51 mm)
minimum clearance
to header
Adapter attached here (not shown)
0 in. to level
of standoffs
Clearance to back &
sides of appliance
Exclaim-36 - 1 in. (25 mm)
Exclaim-42 - 1 1/2 in. (38 mm)
(except at nailing flanges
where it is 1/2 in. [13 mm])
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exclaim-42

Table of Contents