Facing Material - Heat & Glo SL-350TRS-D Owner's Manual

Hearth and home technologies fireplace owner's manual
Table of Contents

Advertisement

B. Facing Material
WARNING
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
• Modifying or covering grilles could cause
temperature rise and fi re hazard.
Finishing materials must not interfere with:
• Air fl ow through grilles or louvers.
• Operation of louvers or doors.
• Access for service.
FACING MATERIAL UP TO 1/2 IN. THICK
MAY BE COMBUSTIBLE - TOP AND SIDES
NON-COMBUSTIBLE
BOARD (INCLUDED)
1 IN.
0 IN.
HIGH TEMPERATURE (300º F / 149º C MIN.)
TOP & SIDE SEAL JOINT
Figure 11.4 Facing Material
WARNING
Risk of Fire
• Non-combustible clearances MUST be
maintained.
• Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
• See Section 11 for proper clearances.
• See Section 1 for combustible/non-
combustible defi nitions.
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07
Note: There are 3 metal tabs holding the non-combustible
board in place for shipping. These tabs are to be cut off or
bent back before fi nishing around the appliance front.
• Black metal appliance front may be covered with
• Do NOT overlap combustible materials onto appliance
• Install combustible materials only up to specified
• Seal joints between the fi nished wall and appliance top
0 IN.
0 IN.
WARNING
Fire Risk.
Finish all edges and fronts to clearances and
specifi cations listed in manual.
noncombustible material only.
front.
clearances on top, front and side.
and sides using only a 300º F minimum sealant.
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-350trs-ipiSl-550trs-ipi-eSl-750trs-ipi-e

Table of Contents