Finishing

A. Mantel Projections
Figure 11.1 shows the minimum vertical and correspond-
ing maximum horizontal dimensions of appliance mantels
or other combustible projections above the top front edge
of the appliance.
All measurements
are in inches
4
3
TOP OF HOOD OR FIREPLACE OPENING
Figure 11.1 Clearances to mantels or other combustibles
above appliance
3-1/2 in.
1/2 in.
NON-COMBUSTIBLE ZONE
Figure 11.2 Non-Combustible Zone
44
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07
CEILING
12
11
10
9
8
32
7
6
5
13
12
11
10
9
8
7
6
5
4
1/2 in.
SHEETROCK
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE
2-7/8 IN.
MINIMUM
Note: Clearance from opening
to perpendicular wall.
Figure 11.3 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
5-3/8 IN.
MINIMUM
Note: Clearance from opening
to perpendicular wall.
Figure 11.4 Wall Projection (Acceptable on one side of opening.)
1/2 IN.
MINIMUM
3 FT. MAXIMUM
3 IN.
MINIMUM
UNLIMITED