Non-Combustible Materials Specifi Cation; Combustible Materials Specifi Cation; Electrical Codes - Heat & Glo SL-550TR-IPI-E Owner's Manual

Hearth & home technologies gas fireplace owner's manual
Hide thumbs Also See for SL-550TR-IPI-E:
Table of Contents

Advertisement

E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed pa-
per, plant fi bers, plastics, or other material that can ignite
and burn, whether fl ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA
C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
8
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. L • 11/08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents