Solar Monitor - Rheem Solar Loline Water Heater Owner's Manual And Installation Instructions

Solar loline water heater
Table of Contents

Advertisement

SOLAR MONITOR

A solar monitor is located on the side of the solar control unit and houses a green and a red LED.
The green LED, marked "Solar", indicates the current operational mode of the solar water heater and the red
LED, marked "Attention", indicates a fault mode.
The green LED will emit either a constant glow or a series of flashes, with a 2 second interval between each
series.
The red LED will emit a series of flashes, with a 2 second interval between each series, only if there is a
particular fault condition with the system.
The operational modes are:
Flashes
Operational Modes
solid green
Standby mode
(remains on)
green
Standby mode
slow pulse
(power on for less than 48 hours)
green
Circulating water through collectors
rapid pulse
Circulating water through collectors
3 x green
(power on for less than 48 hours)
no green
Power outage or call for service
(remains off)
If the power supply to the solar control unit is on and the green LED is off or the red LED is flashing, this
indicates there may be a fault with the water heater. The red LED may emit up to six flashes in each series
of flashes.
Notes:
If the system is in standby mode with the green LED emitting either a constant glow or slow pulsing
flashes (circulator is off) and the solar storage tank is full of hot water, the red LED may simultaneously
emit a constant glow if solar radiation is still being received by the solar collectors. This does not indicate
a fault. The red LED will go out when the temperature in the solar collectors decreases.
During periods of high solar radiation and the circulator activates after having been off (the green LED
will emit either a rapid pulse or a series of three flashes), it is possible the red LED may simultaneously
emit a rapid pulse for a period of up to ten (10) minutes. This does not indicate a fault.
If the red LED continues to emit a rapid pulse for longer than ten (10) minutes, or emits a series of flashes,
then count the number of flashes and phone Rheem Service or their nearest Accredited Service Agent to
arrange for an inspection.