ANODE INSPECTION

The anode installed in your water heater will slowly dissipate whilst protecting the cylinder. The life of the
water heater cylinder may be extended by arranging for an authorised person to inspect the anode and
replace if required.
The suggested time after installation when the anode should be inspected is 8 years.
For water supplies which are either softened, desalinated or where the water supply may alternate between
a water tank and a reticulated public supply or another supply, it is recommended the anode be inspected
3 years earlier than shown (refer to
CAUTION
If the water supply has a TDS greater than 150 mg/L and a green anode has not been changed to a black
anode, or if the TDS is greater than 600 mg/L and the anode has not been changed to a blue anode, there is
the possibility the anode may become overactive and hydrogen gas could accumulate in the top of the water
heater during long periods of no use.
If, under these conditions, the water heater has not been used for two or more weeks the following
procedure should be carried out before using any electrical appliances (automatic washing machines and
dishwashers) which are connected to the hot water supply.
The hydrogen, which is highly flammable, should be vented safely by opening a hot tap and allowing the
water to flow. There should be no smoking or naked flame near the tap whilst it is turned on. Any hydrogen
gas will be dissipated. This is indicated by an unusual spurting of the water from the tap. Once the water
runs freely, any hydrogen in the system will have been released.

SATURATION INDEX

The saturation index is used as a measure of the water‟s corrosive or scaling properties.
In a corrosive water supply, the water can attack copper parts and cause them to fail.
Where the saturation index is less than –1.0, the water is very corrosive and warranty does not apply to a
copper sheathed heating unit or a solar collector in a direct solar water heater system. A corrosion resistant
heating unit must be used for warranty to apply to the heating unit.
In a scaling water supply calcium carbonate is deposited out of the water onto any hot metallic surface.
Where the saturation index exceeds +0.40, the water is very scaling. An expansion control valve must be
fitted on the cold water line after the non-return valve to protect and for warranty to apply to the temperature
pressure relief valve and water heater cylinder. Solar collectors in a direct solar water heater system should
be covered when the water heater is not intended to be used for more than two weeks.
Where the saturation index exceeds +0.80, warranty does not apply to a standard watts density heating unit
or a solar collector in a direct solar water heater system. A low watts density heating unit must be used for
warranty to apply to the heating unit.
Water which is scaling may be treated with a water softening device to reduce the saturation index of the
water.
Refer to the
Saturation Index chart
Contact Rheem Service or their nearest Accredited Service Agent if a replacement heating unit is required.
Refer to the
cold water connection detail on page
"Anode"
on page 14).
on page 16.
35 for the position of the expansion control valve.
15
WATER SUPPLIES