Advertisement

7100FP EPA Woodburning Fireplace
3
Framing and Clearances
WARNING
Fire Risk
Provide adequate clearances.
Around air openings
To combustibles
For service access.
Locate fireplace away from traffic areas.
A. Selecting Fireplace Location
Several options are available to you when choosing a loca-
tion for your fireplace. This fireplace may be used as a room
divider, installed along a wall, across a corner or used in an
exterior chase. See Figure 10.1.
Locating the fireplace in a basement, near frequently opened
doors, central heat outlets or returns, or other locations of
Note:
A minimum 1/2 in. air clearance must be maintained at the
back and 1 in. minimum clearance to the sides of the fireplace
assembly.
Chimney sections at any level require a 2 in. minimum air
space clearance between the framing and chimney sections.
E
F
Model
#7100FP
(Dimensions for
finished walls)
Figure 10.1 Fireplace Locations
Page 10
D
Across a corner
A
C
24 in.
(610mm)
As a
H
room
A
divider
48 in.
(1219mm)
B
G
A
B
C
41-7/8
16
89-1/2 63-5/16 22-7/16 44-3/4 14-1/16 55-15/16 50-7/8
in.
1063
406
2273
mm
Note:
• Illustrations and photos reflect typical installations and
are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to individual
design preference.
Hearth & Home Technologies reserves the right to alter
its products.
considerable air movement can affect the performance and
cause intermittent smoke spillage from the front of the fire-
place when no outside air is used. Outside air must be used
for combustion. The 7100FP comes equipped with an out-
side air inlet to feed combustion air from outside the home,
along with an outside air termination cap. Consideration
should be given to these factors before deciding on a loca-
tion. See Sections 2 and 10.
Note:
In addition to these framing dimensions, also reference the
following sections:
Clearances (Section 3.B.)
Mantel (Section 8.F.)
Fireplace Dimensions (Section 12.A.)
In an exterior chase
or projecting into a
garage
Along a wall
F
D
E
1608
570
1137
433-1390G
24 in.
(610mm)
A
B
B
I
A
24 in.
(610mm)
G
H
I
357
1421
1292
September 1, 2008
R