Wiring the Wall Switch
Install the provided control wire from the fi replace to the
switch location. (Control wire for Heatilator products is
supplied with the fi replace).
NOTICE: Do not to stress the wire around tight or sharp
corners. Do not run the control wire adjacent to existing
or future phone, data, cable, or electrical lines. The
wire should not come into contact with any part of the
fi replace exterior with the exception of where it exits the
outer wrap.
ORANGE
GROUND
BLACK
IPI
VALVE
FLAME
SOLENOID
ADAPTER WIRES
* May be labeled as "W" or "Y".
Figure 12.2 Intellifi re (IPI) Wiring Diagram
54
BLACK
WHITE
BROWN
GREEN
1
2
IPI
3
MODULE
4
5
6
7
8
RED
FLAME ON
RED
FLAME HIGH/LOW
AC
PLUG
AUX
CONNECTION
Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08
Feed the wire to the electrical junction box and through
a provided or approved strain relief.
Connect the wires to the terminals as shown in Figure
12.2. Do not over-tighten.
Using the screws provided, mount the switch to the
electrical junction box right side up.
Install provided cover plate using the screws provided.
Do not use a substitute cover even though it may fi t. The
provided one is specifi cally designed for the automatic
(thermostat) function of the unit.
BATTERIES
BLACK
RED
YELLOW OR
WHITE
BROWN
BROWN
RED
3V DC
BLACK
ORANGE
ORANGE
BLACK
BLACK
GROUND PIGTAIL
GREEN
RED
REAR VIEW
GREEN
*
*
FRONT VIEW
YELLOW
TEMPERATURE
YELLOW
SENSOR SWITCH
FAN THERMOSTAT
CONNECTION
BLACK
FAN

Hide quick links: