Hearth and Home Technologies BE-36-C Installer's Manual page 21

Hearth & home technologies fireplace installers guide
Hide thumbs Also See for BE-36-C:
Table of Contents

Advertisement

BE-36-C
BE-36-C, BE-36-C LP
H + H
(MAX.)
V (MIN.)
1
o
4' (1.22m)
90
Elbow on Top 2.5' (863mm)
6' (1.86m)
1' (305mm)
8' (2.48m)
2' (610mm)
3' (914mm)
12' (3.72m)
16' (4.8m)
4' (1.22m)
5' (1.52m)
16' (4.8m)
H + H
MAX. = 16' (4.8m)
1
V + H + V
+ H
1
Use SL D-Series
components only.
V 1
H 1
NOTE: There MUST be a 25% reduc-
tion in total H when using flex vent
except when using the simple up and
out installation (see Figure 7).
Use SL D-Series
components only.
Figure 15.
Venting with Three 90° elbows
Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05
BE-36-C LP
H (MAX.)
H + H
(MAX.)
1
5' (1.52m)
2.5' (863mm)
5' (1.52m)
4' (1.22m)
8' (2.48m)
6' (1.86m)
12' (3.72m)
8' (2.48m)
16' (4.8m)
16' (4.8m)
16' (4.8m)
MAX. = 40' (12.2m)
1
H
1
BE-36-C
V (MIN.)
H + H
90
o
Elbow on Top 2.5' (863mm)
1' (305mm)
3' (914mm)
2' (610mm)
4' (1.22m)
3' (914mm)
6' (1.86m)
4' (1.22m)
8' (2.48m)
5' (1.52m)
16' (4.8m)
H + H
MAX. = 16 FT (4.8m)
1
V + V
+ H + H
MAX. = 40 FT (12.2m)
1
1
BE-36-C LP
(MAX.)
H + H
(MAX.)
1
1
2.5' (863mm)
2.5' (863mm)
4' (1.22m)
6' (1.86m)
8' (2.48m)
16' (4.8m)
H
H
V
1
V
V
21