Heat & Glo 6000GL-IPI-S Owner's Manual page 31

Installation and operation
Hide thumbs Also See for 6000GL-IPI-S:
Table of Contents

Advertisement

Rear Vent - Vertical Termination
One Elbow
V
1
Figure 7.17
Two Elbows
V
2
Figure 7.18
H
1
INSTALLED
HORIZONTALLY
H
2
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08
V
Minimum
1
6 in.
1 ft.
2 ft.
3 ft.
4 ft.
5 ft.
V
+ H
= 40 ft (12.2 m) Maximum
1
1
H
= 8 ft (2.4 m) Maximum
1
H
+ H
Maximum
1
2
Back to Back 90º Elbows
2 ft
610 mm
4 ft
1.2 m
6 ft.
1.8 m
8 ft.
2.4 m
V
+ H
= 40 ft (12.2 m) Maximum
1
1
H
+ H
= 8 ft (2.4 m) Maximum
1
2
H
1
H
Maximum
1
152 mm
2 ft.
610 mm
305 mm
3 ft.
914 mm
610 mm
5 ft.
1.5 m
914 mm
7 ft.
2.1 m
1.2 m
8 ft
2.4 m
1.5 m
8 ft
2.4 m
V
Minimum
1
3 ft.
914 mm
6 ft.
1.8 m
9 ft.
2.7 m
12 ft.
3.7 m
15 ft.
4.6 m
31