3.
Use the following example to verify the target setting:
# iscsiadm list target-param
Target: iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.b1.01.50014380025c417d
#iscsiadm modify target-param –p maxrecvdataseglen=65536 iqn.1986-03.com.hp:fcgw.mpx200.
0834e00028.b1.01.50014380025c417d
# iscsiadm list target-param -v iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.b1.01.
50014380025c417d
Target: iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.b1.01.50014380025c417d
Alias: -
Bi-directional Authentication: disabled
Authentication Type: NONE
Login Parameters (Default/Configured):
Configured Sessions: 1

Monitoring the multipath devices

After HP P6000 Command View has presented the virtual disks to the Solaris host, enter the
following commands to monitor the configuration:
1.
iscsiadm list target -S
This command lists targets with their presented LUNs. In a multipath environment, the same
LUN should appear under different P6000 EVA port targets from the same controller.
Example:
iscsiadm list target -S
Target: iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.b2.01.50014380025c4179
Target: iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.b1.01.50014380025c417d
2.
mpathadm list lu
This command displays the total and operational path count for each logical unit. It displays
both the controller and device path counts.
Example:
#mpathadm list lu
88
MPX200 iSCSI configuration rules and guidelines
Data Sequence In Order: yes/-
Data PDU In Order: yes/-
Default Time To Retain: 20/-
Default Time To Wait: 2/-
Error Recovery Level: 0/-
First Burst Length: 65536/-
Immediate Data: yes/-
Initial Ready To Transfer (R2T): yes/-
Max Burst Length: 262144/-
Max Outstanding R2T: 1/-
Max Receive Data Segment Length: 8192/65536
Max Connections: 1/-
Header Digest: NONE/-
Data Digest: NONE/-
Alias: -
TPGT: 0
ISID: 4000002a0000
Connections: 1
LUN: 120
Vendor:
HP
Product: HSV300
OS Device Name: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
Alias: -
TPGT: 0
ISID: 4000002a0000
Connections: 1
LUN: 120
Vendor:
HP
Product: HSV300
OS Device Name: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
/scsi_vhci/array-controller@g50014380025c4170
Total Path Count: 2
Operational Path Count: 2