Communication Setup; Ps • Data Setup - Panasonic WJ-HD500A Operating Instructions Manual

Digital disk recorder
Hide thumbs Also See for WJ-HD500A:
Table of Contents

Advertisement

Available languages

Available languages

COMMUNICATION SETUP

The procedures described below let you set the parame-
ters for the Disk Recorder to communicate with external
devices.
1. Move the cursor to COMMUNICATION SETUP in the
WJ-HD500 SETUP menu by pressing the C or D but-
ton, then press the SET button.
The COMMUNICATION SETUP menu shown below
appears on the monitor screen.
8 COMMUNICATION SETUP
PS•Data SETUP
RS232C SETUP
NETWORK SETUP
IP ADDRESS
NETMASK
GATEWAY
2. Select an item or item parameter in the menu by press-
ing the D or C button.
3. To return to the previous WJ-HD500 SETUP menu,
press the SETUP/ESC button.
PS
Data Setup
These items let you set the parameters for communication
between the System Controllers and the Disk Recorders
when the system is controlled with the PS
(Panasonic Security Data).
1. Move the cursor to PS
CATION SETUP menu by pressing the C or D button,
then press the SET button.
The PS
Data SETUP menu shown below appears on
the monitor screen.
8-1 PS•Data SETUP
UNIT ADDRESS
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
WAIT TIME
ALARM DATA
CAMERA NUMBER SETUP
68
192.168.000.010
255.255.255.000
192.168.000.001
Data mode
Data SETUP in the COMMUNI-
001
9600
8
NONE
1
OFF
1S
2. Select an item or item parameter in the menu by press-
ing the D or C button.
3. To return to the previous setup menu, press the
SETUP/ESC button.
Unit Address Setting
This item lets you set the unit address of the Disk Recorder
in the system for RS-485 communication.
1. Move the cursor to the UNIT ADDRESS parameter by
pressing the D or C button.
2. Select the unit address number to be used for RS-485
communication by pressing the + or - button.
Select a parameter value between 001 and 099.
The factory default setting is 001.
Baud Rate
This item lets you set the transmission speed for RS-485
communication.
1. Move the cursor to the BAUD RATE parameter by
pressing the D or C button.
2. Select the desired transmission speed shown below by
pressing the + or - button.
↔ 2 400 ↔ 4 800 ↔ 9 600 ↔19 200 ↔ 38 400 ↔
The factory default setting is 9 600 bps.
Data Bit
This item lets you set the number of data bits for RS-485
communication.
The factory default setting is 8 bits and fixed.

Advertisement

Chapters

Table of Contents
loading

Table of Contents