[Basic parameter list]
No.
Title
Function
Automatic
1
acceleration/deceleration
2
Automatic V/f mode setting
Operation command mode
3
selection
Speed setting mode
4
Selection
5
FM terminal meter selection
FM terminal meter
6
adjustment
Standard setting mode
7
selection
Forward/reverse selection
8
(At panel control only)
9
Acceleration time #1
10
Deceleration time #1
11
Maximum frequency
12
Upper limit frequency
13
Lower limit frequency
14
Base frequency #1
Motor control mode
15
selection
16
Manual torque boost
Selection of electronic
17
thermal protection
characteristics
18
Preset-speed # 1
19
Preset-speed # 2
20
Preset-speed # 3
21
Preset-speed # 4
22
Preset-speed # 5
23
Preset-speed # 6
24
Preset-speed # 7
25
Extended parameter
26
Automatic edit function
Adjustment range
: Manual acceleration/deceleration
: Automatic acceleration/deceleration
: (0 is always displayed.)
: Automatic torque boost + auto-tuning
: Sensorless vector control (speed) + auto-tuning
: Automatic energy-saving + auto-tuning
: Terminal block enabled
: Operating panel enabled
: Common serial communication option enabled
: Serial communication RS485 enabled
: Communication add-on cassette option enabled
: VI (voltage input)/II (current input)
: RR (volume/voltage input)
: RX (voltage input)
: RX2 (voltage input) (optional)
: Operating panel input
: Binary/BCD input(optional)
: Common serial communication option(FA01)
: Serial communication RS485(FA05)
: Communication add-on cassette option(FA07)
: Up-down frequency
: Pulse input #1 (optional)
:
: 50Hz standard setting
: 60Hz standard setting
: Factory default setting
: Trip clear
: Clearing accumulating operation time
: Initialization of type form information
: Memorization of user-defined parameters
: Reset of user-defined parameters
: Forward,
: Reverse
() [s]
() [s]
[Hz]
[Hz]
[Hz]
[Hz]
: Constant torque
: Variable torque mode
: Automatic torque boost
: Sensorless vector control (speed)
: Automatic torque boost + automatic energy-saving
: Sensorless vector control (speed) + automatic energy-saving
: V/f 5-points setting
:Sensorless vector control (speed/torque switching)
: PG feedback vector control (speed/torque switching)
: PG feedback vector control (speed/position switching)
[%]
Setting
Type
Overload protection
Standard
motor
not protect
not protect
VF motor
(special
not protect
motor)
not protect
[Hz]
[Hz]
[Hz]
[Hz]
[Hz]
[Hz]
[Hz]
Setting of extended
To search parameters different from default value.
D-3
Overload stall
protect
not stall
protect
stall
not stall
stall
protect
not stall
protect
stall
not stall
stall
Default
Reference
setting
section
5.1.1
5.2
5.3
5.3
5.4
5.4
5.5
5.6
See J-28
5.1.2
See J-28
5.1.2
5.7
5.8
5.8
5.9
5.10
See J-28
5.12
5.13
5.14
4.1.2
4.1.2