6.28 Meter output

6.28.1 Setting of meter outputs



Refer to 5.4 for details.

6.28.2 Setting of optional meter outputs









6.28.3 Pulse output to meters



The function set with  is output from FP terminal.
Set a desired number of output pulses as  with
reference to the following table. Refer to 5.4 about adjustment level.
Ex.)Output Running frequency(0 80Hz) at 0 10kHz
Setting: =, =, =
Title
FP terminal meter

selection
FP terminal meter

adjustment
Note) ON pulse width is fixed at a value that depends on the setting of .(about 50~70%)
The data of current, torque, etc. are limited by 200 %.
AM terminal meter selection
AM terminal meter adjustment
Optional analog terminal #1 meter selection
Optional analog terminal #1 meter adjustment
Optional analog terminal #2 meter selection
Optional analog terminal #2 meter adjustment
Optional analog terminal #1 meter offset
Optional analog terminal #2 meter offset
Optional analog terminal #2 sign selection
FP terminal meter selection
FP terminal meter adjustment
Function
0: Running frequency
1: Frequency command
2: Current indication
3: DC voltage
4: Output voltage
5: After-compensation frequency
6: Speed feedback (real-time value)
7: Speed feedback (1 second filter)
8: Torque
9: Torque reference
10: Internal torque reference (*1)
11: Torque current
12: Exciting current
13: PID feedback value
14: Motor overload factor (OL2 data)
15: Inverter overload factor (OL1 data)
16: PBr overload factor (PBrOL data)
17: PBr load factor (pulse duty)
18: Input power
19: Output power
20: Peak output current
21: Peak DC voltage
22: Motor counter dummy PG
23: Position pulse
24: PR input
25: VI/II input
26: RX input
27: RX2 input
28: FM output
29: AM output
30: Fixed output for meter adjustment
31: Analog output for communication
32:Acc/dec torque removal
  [kHz]
Adjustment range
F-65
Function
These parameters are used
to set the pulse output
function and the number of
pulses output from the output
terminal FP.
Adjustment level Default setting
(a)
(a)
(b)
(b)
(b)
(a)
(a)
(a)
(b)
(b)
(b)
(b)
(b)
(a)
(c)
(c)
(c)
(c)
(e)
(e)
(b)
(b)
(d)
(d)
(c)
(c)
(c)
(c)
(c)
(c)
(c)
(b)
