Fig. 8
to combustibles
3 ft.
to combustibles
Fig. 9
Venting
This method provides excellent venting for normal op-
eration and allows the stove to be installed closest to the wall.
Two inches from the wall is safe; however, four inches allows
better access to remove the rear panel. The vertical portion of
the vent should be three to five feet high. This vertical section
will provide natural draft in the event of a power failure.
3 ft.
This method also provides excellent venting for normal
operation but requires the stove to be installed farther from the
wall. The vertical portion of the vent should be three to five feet
high and at least three inches from a combustible wall. This
vertical section will provide natural draft in the event of a power
failure.
KEEP COMBUSTIBLES (SUCH AS GRASS,
LEAVES, ETC.) AT LEAST 3 FEET AWAY FROM
THE FLUE OUTLET ON THE OUTSIDE OF THE
BUILDING.
10
#1 Preferred method
#2 Preferred method
CAUTION
P38+ Pellet Stove