Distributor And Coil Unit - International Harvester Company CUB Operator's Manual

Hide thumbs Also See for CUB:
Table of Contents

Advertisement

ELECTRICAL SYSTEM
DISTRIBUTOR AND COIL UNIT
MAGNETO.
Continued
Installing
and Timing the Magneto to the Engine
.Continued
Greasing the Breaker Mechanism and Checking
the Paints
1(lust. 30
Magneto removed showing
Impulse coupling.
Illust. 30A
Adlusting
the breaker paints.
5.
Tighten
mounting
clip nut "D" and bolt
"E"
(1IIust. 29) securely.
If the spark plug cables
have been removed
for any reason,
attach the
cables
to the engine
and magneto.
Start
by con-
necting
the No.
I cylinder
spark plug to the
socket
marked
1'1" on the distributor
cap In
Illust.27). Then connect
the No.3
socket
with
the No.3
cylinder;
next the No.4
socket
with
the No.4
cylinder,
and last,
the No.2
socket
with the No.2
cylinder.
See Illusts. 27 and 29A.
It is important
that the breaker
chamber
be
kept clean because
oil on the breaker
points
will
cause rapid
burning.
Remove
the distri-
butor
cap,
distributor
rotor,
and the breaker
cover
for breaker
chamber
inspection.
See Illust.
30A. Care
should be taken,
when removing
the
breaker
cover,
to keep dirt
from
entering
the
breaker
chamber.
Be sure the chamber
is
clean and that the breaker
points
are in good
condition
and have the proper
opening.
6. Connect the switch cable to the magneto
terminal.
S.. "A", Illust. 29.
Never use emery cloth or sandpaper to
clean
the points.
To dress
the points.
use
a
sharp fine file.
If the points are worn exces-
sively.
replace
both
points.
7. To check the timing,
crank the engine
slowly until the top dead center of the No.1
cylinder
is reached; at this time the impulse
coupling should just trip.
Never time before
top dead center.
Fill
the recess
in the breaker
post with IH
High Temperature
Grease
(21372-D)
and pack
a small
quantity
of the same grease
iIJ back of
the breaker
arm rubbing
block and apply a
light
coating
of the same grease
on the lobes
and flats
of the breaker
cam.
See Illusts. 30A and 31.
See your International
Harvester
dealer.
8. The magneto is now correctly
wired and
timed.
9. Push cable
"B"
back into the socket
in
the coil cover.
See Illust. 29A.
30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cub lo-boy