Download Print this page

Memory Channel - HP Compaq AlphaStation DS20E Quickspecs

Advertisement

QuickSpecs
Options
Tru64 UNIX Systems
Tru64 UNIX Systems
Tru64 UNIX Systems
Tru64 UNIX Systems
(V5.0A and later)
Tru64 UNIX Systems
Tru64 UNIX Systems
Tru64 UNIX Systems
Tru64 UNIX Systems
(V4.0G and earlier)
OpenVMS Systems
OpenVMS Systems
OpenVMS Systems
OpenVMS Systems
Configuring Information
Configuring Information
Configuring Information
Configuring Information

MEMORY CHANNEL

MEMORY CHANNEL
MEMORY CHANNEL
MEMORY CHANNEL
Controller
Controller
Controller
Controller
MEMORY CHANNEL
MEMORY CHANNEL
MEMORY CHANNEL
MEMORY CHANNEL
Power Cords
Power Cords
Power Cords
Power Cords
Each system node in the cluster requires a TruCluster Server license (QL-6BRAC-AA)
Requires a minimum of Tru64 UNIX V4.0F with TruCluster V1.6 or later
Each system node in the cluster requires a TruCluster Production Server
(QB-3RLAE-AA) or TruCluster MEMORY CHANNEL software license (QB-4ZCAE-AA)
TruCluster MEMORY CHANNEL license (QB-4ZCAG-AA), normally used for high performance technical
computing applications, not required if systems have a TruCluster Production Server license (QB-3RLAE-
AA)
Requires OpenVMS V7.1-2 or later and OpenVMS Cluster license (QL-MUZAC-AA)
Up to two PCI to System Area Network adapters (CCMAB-AA) are supported in a single system
Two-node clusters can be configured by ordering a CCMAB-AA for each node and one BN39B-04 or
BN39B-10 cable; cable connects directly to CCMAB-AA in each node.
For a two-node cluster that will not need to be rebooted when adding additional members, order one
CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub
for the cluster.
For three- or four- node clusters, order one CCMAB-AA adapter and one
BN39B-04 or BN39B-10 cable for each node, and one CCMHB-AA hub for the cluster
CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight
system nodes can be achieved by adding up to four additional CCMLB-AA line cards
If nodes must be separated by a distance longer than standard copper cables allow the CCMFB option
converts the output of the standard CCMAB controller or CCMLB line card to single-mode fiber optic
cable. The fiber optic connection may be up to 2,000 meters long between two CCMAB controllers
connected in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The
connection from the CCMHB hub to a second system may also be 3,000 meters.) The CCMFB option
requires a second PCI slot in the system from which it draws power only. It is normally connected to the
corresponding CCMAB controller with the short BN39B-01 cable. The CCMFB is also used in the
CCMHB hub where it occupies a slot normally used by the CCMLB line card, limiting expansion to four
radial fiber optic connections.
If two CCMAB-AA's are configured in each system, a second CCMHB-AA is required.
PCI System Area Network Controller, maximum two
System Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan,
and US operations- for other regions, order appropriate power cord from list below
Expansion line card for CCMHB hub
1-meter cable for CCMAB and CCMHB
4-meter cable for CCMAB and CCMHB
10-meter cable for CCMAB and CCMHB
Copper-to-single mode fiber optic converter – 5V (clock not affected)
Australia, New Zealand (103541-011)
Central Europe
Denmark (103541-481)
Egypt, India (103541-AR1)
Ireland, United Kingdom
Israel
Italy (103541-461)
Switzerland (103541-511)
DA - 10445
North America — Version 37 — October 24, 2003
Compaq AlphaServer DS20E
Compaq AlphaServer DS20E
Compaq AlphaServer DS20E
Compaq AlphaServer DS20E
Compaq AlphaStation DS20E
Compaq AlphaStation DS20E
Compaq AlphaStation DS20E
Compaq AlphaStation DS20E
CCMAB-AA
CCMHB-AA
CCMLB-AA
BN39B-01
BN39B-04
BN39B-10
CCMFB-AA
BN19H-2E
BN19C-2E
BN19K-2E
BN19S-2E
BN19A-2E
BN18L-2E
BN19M-2E
BN19E-2E