connect
neutral
wire
Place hooked end of neutral wire (white
or center) (C) of direct wire cable under
center terminal block screw (B). Squeeze
hooked end together. Tighten screw.
4, Connect
remaining
wires
Connect
neutral ground
wire
and neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down
screw. Now, go to
"Venting Requirements".
OPTIONAL
3=WIRE
CONNECTION
You must verify with a qualified
electrician that this grounding
method is acceptable before connecting.
ground
wire and neutral wire
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
4, Connect
external
ground
wire
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
"Venting Requirements".
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).