LOCATION
REQUIREMENTS
Explosion Hazard
Keep flammable
materials
and vapors, such as
gaso|ine, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[]
A location allowing for proper exhaust installation. See
"Venting Requirements."
[]
A separate 30 amp circuit.
[]
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer. See
"Electrical Requirements."
[]
Floor must support dryer weight of 200 Ibs. (90.7 kg). Also
consider weight of companion appliance.
[]
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), clothes may not
tumble properly and automatic sensor cycles may not
operate correctly.
[]
For a garage installation, place dryer at least 18" (457 mm)
above floor.
[]
Steam models only: Cold water faucets located within 4 ft.
(1.2 m) of the water fill valves, and water pressure of 20-100
psi (137.9-689.6
kPa). You may use the water supply for your
washer using the "Y" connector and short hose (if needed)
which are provided.
For each arrangement,
consider allowing more space for ease
of installation and servicing; spacing for companion
appliances
and clearances for walls, doors, and floor moldings. Space
must be large enough to allow door to fully open. Add spacing
on all sides of dryer to reduce noise transfer. If a closet door
or Iouvered door is installed, top and bottom air openings
in door are required.
iMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures
below
45 ° F (7° C). Lower temperatures
may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
INSTALLATION CLEARANCES
Location must be large enough to allow dryer door to open fully.
DRYER DIMENSIONS
Models with riser
-_
221/4,,-_
(565 ram)
_-_d
30"_
(783 mm2_y-
441/2"
(1t30
ram)
,
1/2"
(!3
turn)
Side view
63/4"
(171 ram}
m
(368 ram) _ 1 11"
4"
(102 turn)
53/8"
I
(137_mm) 1
(25 ram)
(279 rnm)
Back
view
Models without riser
(565 rnm}
-_
30"_
Side view
42_
"
(1080
mm)
1_/8"
(35 ram)
2"
(51 ram)
3 s/8"
I
(368
}-_1
11"
_-(25turn}
(279 mm)
Back
view
Bottom
view:
31/4"
(83 _nm)
/
x
.j-[_._._._._._._.J__
_,1-141/2"-_ " =-141/2 ' '-_-
(368 ram) (368 ram)
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See "Venting
Requirements."
4