YOKOGAWA EJX Series User Manual page 48

Differential pressure and pressure transmitters
Table of Contents

Advertisement

No.
Parameter name
M20 ISOL MATL
Capsule material
M21 FILL FLUID
Fill fluid
M22 GASKET MATL
Gasket material
M23 PRO CON MATL
Flange material
M24 D-VENT MATL
Vent plug material
M25 PRO CON TYPE
Process connection
type
M26 RS ISOL MATL
Remote seal material
M27 PRO CON SIZE
Flange size
M28 NUM RS
Number of remote seal
M29 RS FILL FLUID
Fill fluid of remote seal
M30 RS TYPE
Remote seal type
M50 MS CODE 1
Model and suffix code 1
M51 MS CODE 2
Model and suffix code 2
M52 MS CODE 3
Model and suffix code 3
M53 MS CODE 4
Model and suffix code 4
M54 MS CODE 5
Model and suffix code 5
M55 MS CODE 6
Model and suffix code 6
M60 SELF CHECK
Self-diagnostics
P
Record
History of errors
P10
ERROR REC 1
Last error
P12
ERROR REC 2
Second recent error
P14
ERROR REC 3
Third recent error
P16
ERROR REC 4
Forth recent error
P60
SELF CHECK
Self-diagnostics
T
CHARACTERIZR
Signal characterizer
setting
T10
S. C. ENABLE
Signal characterizer
permission
T11
NUM OF POINT
Number of coordinates
T20
X START (FIX)
Start point of X
T21
Y START (FIX)
Start point of Y
T22
X1
Coordinate 1 of X
T23
Y1
Coordinate 1 of Y
T24
X2
Coordinate 2 of X
T25
Y2
Coordinate 2 of Y
T26
X3
Coordinate 3 of X
T27
Y3
Coordinate 3 of Y
T28
X4
Coordinate 4 of X
T29
Y4
Coordinate 4 of Y
T30
X5
Coordinate 5 of X
T31
Y5
Coordinate 5 of Y
T32
X6
Coordinate 6 of X
T33
Y6
Coordinate 6 of Y
T34
X7
Coordinate 7 of X
T35
Y7
Coordinate 7 of Y
T36
X8
Coordinate 8 of X
T37
Y8
Coordinate 8 of Y
T38
X9
Coordinate 9 of X
T39
Y9
Coordinate 9 of Y
T40
X END (FIX)
End point of X
T41
Y END (FIX)
End point of Y
T60
SELF CHECK
Self-diagnostics
*1:
R/W: R = Read only, W = Read & Write
*2:
The default value shows MWP (Maximum working pressure) of the capsule.
Since the working pressure limit varies according to the Model, refer to the General Specifications section in each user's manual.
Item
R/W
*1
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
R
See A60
W
See A60
W
See A60
W
See A60
W
See A60
R
See A60
W
INHIBIT or ENABLE
W
0 to 9
R
0.00%
R
0.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
W
0.00 to 100.00%
R
100.00%
R
100.00%
R
See A60
<8. Parameter Summary>
Content
Default value
GOOD
GOOD
GOOD
GOOD
INHIBIT
0
10.00
10.00
20.00
20.00
30.00
30.00
40.00
40.00
50.00
50.00
60.00
60.00
70.00
70.00
80.00
80.00
90.00
90.00