YOKOGAWA EJX Series User Manual page 46

Differential pressure and pressure transmitters
Table of Contents

Advertisement

No.
Parameter name
G
ALARM SET
Alarm setting
G10 P AL MODE
Alert mode
G11 P HI. AL VAL
High side alert value
G12 P LO. AL VAL
Low side alert value
G20 SP AL MODE
Static pressure alert
mode
G21 SP HI. AL VAL
High side alert value of
SP*
G22 SP LO. AL VAL
Low side alert value
of SP
G30 T AL MODE
Temperature alert mode
G31 T HI. AL VAL
High side alert value of
temperature
G32 T LO. AL VAL
Low side alert value of
temperature
G50 AUTO RECOVER
Auto-recover from
sensor error
G60 SELF CHECK
Self-diagnostics
H
AUTO SET
Automatic setup
H10 AUTO P LRV
Lower range value auto
setup
H11
AUTO P URV
Upper range value auto
setup
H20 AUTO SP LRV
SP lower range value
auto setup
H21 AUTO SP URV
SP upper range value
auto setup*
H60 SELF CHECK
Self-diagnostics
I
DISP SET
Display setting
I10
DISP OUT1
LCD output 1
I11
DISP OUT2
LCD output 2
I12
DISP OUT3
LCD output 3
I13
DISP OUT4
LCD output 4
I20
P DISP MODE
% display mode
I21
PRES % RESO
% display resolution
I30
ENGR. UNIT
User set engineering
unit
I31
EASY EU SET
Engineering unit select
I32
ENGR. EXP
Exponents
I33
ENGR. LRV
User set lower range
limit
I34
ENGR. URV
User set upper range
limit
I35
ENGR. POINT
Decimal place of user
set
I40
BAR INDICATR
Bar indicator
I41
POWER ON INF
Display when powering
on
I60
SELF CHECK
Self-diagnostics
*1:
R/W: R = Read only, W = Read & Write
*2:
The default value shows MWP (Maximum working pressure) of the capsule.
Since the working pressure limit varies according to the Model, refer to the General Specifications section in each user's manual.
Item
R/W
*1
W
INHIBIT, HI. AL DETECT,
LO. AL DETECT, or HI/LO.
AL DETECT
W
-32000 to 32000, unit
specified in C20
W
-32000 to 32000, unit
specified in C20
W
INHIBIT, HI. AL DETECT,
LO. AL DETECT, or HI/LO.
AL DETECT
W
-32000 to 32000, unit
2
specified in D30
W
-32000 to 32000, unit
specified in D30
W
INHIBIT, HI. AL DETECT,
LO. AL DETECT, or HI/LO.
AL DETECT
W
-50 to 130
W
-50 to 130
W
OFF or ON
R
See A60
W
-32000 to 32000, unit
specified in C20
W
-32000 to 32000, unit
specified in C20
W
-32000 to 32000, unit
specified in D30
W
-32000 to 32000, unit
2
specified in D30
R
See A60
W
PRES, PRES %, ENGR.
PRES, SP, or SP %
W
PRES, PRES %, ENGR.
PRES, SP, SP %, or ---
W
See I11
W
See I11
W
LINEAR or SQUARE ROOT LINEAR
W
NORMAL or HIGH
RESOLUTION
W
8 alphanumeric characters
W
W
---, ×10, ×100, ×1000
W
-32000 to 32000, unit
specified in I30
W
-32000 to 32000, unit
specified in I30
W
0 to 4
W
OFF or ON
W
OFF or ON
R
See A60
<8. Parameter Summary>
Content
Default value
INHIBIT
100.000 kPa
-100.000 kPa
INHIBIT
0.00000 MPa
INHIBIT
120 degC
-40 degC
ON
As specified
As specified
0.00000 MPa
PRES %
---
---
---
NORMAL
---
0.00
100.00
1
ON
ON
44
Applicable model
F
P
L
IM 01C25A01-01E