YOKOGAWA EJX Series User Manual page 47

Differential pressure and pressure transmitters
Table of Contents

Advertisement

No.
Parameter name
J
ADJUST
Adjusting data
J09
ADJ UNIT
Pressure adjusting unit
select
J10
ADJ PRES
Adjustment reference
pressure
J11
P ZERO ADJ
Automatic zero
adjustment
J12
P SPAN ADJ
Automatic span
adjustment
J15
P ZERO DEV
Manual zero adjustment
J16
P SPAN DEV
Manual span
adjustment
J20
ADJ SP
Adjustment reference
pressure of SP
J21
SP ZERO ADJ
Automatic SP zero
adjustment
J22
SP SPAN ADJ
Automatic SP span
adjustment*
J25
SP ZERO DEV
Manual SP zero
adjustment
J26
SP SPAN DEV
Manual SP span
adjustment
J40
OUTPUT 4mA
4 mA adjustment
J41
OUTPUT 20mA
20 mA adjustment
J45
AMP TEMP
Amplifier temperature
J50
ADJ WHO
Adjustment information
J51
ADJ DATE
Adjustment information
J52
ADJ LOC
Adjustment information
J53
ADJ DESC
Adjustment information
J55
EXT ZERO ADJ
External zeroing
permission
J56
CLEAR ADJ
Clear adjustment
J60
SELF CHECK
Self-diagnostics
K
TEST
Test parameters
K10
OUTPUT X %
Test output % setting
K40
DO TEST
Test contact output
K45
TEST TIME
"OUTPUT X %" and
"DO TEST" duration
time selection
K50
TEST KEY1
Special maintenance
parameter
K51
TEST KEY2
Special maintenance
parameter
K52
TEST KEY3
Special maintenance
parameter
K53
TEST KEY4
Special maintenance
parameter
K60
SELF CHECK
Self-diagnostics
M
DEVICE INFO
Device information
M10 SERIAL NO.
Serial number
M11 MFTR. DATE
Manufactured date
M12 EXTRA NO.
Customization number
M15 SOFT REV
Software revision
M16 BRAIN REV
BRAIN protocol revision
M17 MEMO1
Memo
M18 MEMO2
Memo
M19 MEMO3
Memo
*1:
R/W: R = Read only, W = Read & Write
*2:
The default value shows MWP (Maximum working pressure) of the capsule.
Since the working pressure limit varies according to the Model, refer to the General Specifications section in each user's manual.
Item
R/W
*1
W
% or PRES UNIT
R
Unit specified in J09
W
-32000 to 32000, unit
specified in J09
W
-32000 to 32000, unit
specified in J09
W
-32000 to 32000, unit
specified in J09
W
-32000 to 32000, unit
specified in J09
R
Unit specified in J09
W
-32000 to 32000, unit
specified in J09
W
-32000 to 32000, unit
2
specified in J09
W
-32000 to 32000, unit
specified in J09
W
-32000 to 32000, unit
specified in J09
W
-10.000 to 10.000%
W
-10.000 to 10.000%
R
Unit specified D40
W
8 alphanumeric characters
W
16 alphanumeric characters
W
8 alphanumeric characters
W
16 alphanumeric characters
W
INHIBIT or ENABLE
W
---, PRES, SP, 4-20mA, or
ALL
R
See A60
W
Within a range between
D20 and D21
W
OFF or ON
W
10 min, 30 min, 60 min,
3 hour, 6 hour, 12 hour
W
W
W
W
R
See A60
R
R
R
R
R
W
16 alphanumeric characters
W
16 alphanumeric characters
W
16 alphanumeric characters
<8. Parameter Summary>
Content
Default value
PRES UNIT
0.00000 kPa
100.000 kPa
100.000 kPa
100.000 kPa
0.00000 MPa
0.00000 MPa
0.00000 MPa
0.000%
0.000%
0 degC
ENABLE
---
0.00%
OFF
10 min
45
Applicable model
F
P
L
8
IM 01C25A01-01E

Hide quick links: