ENGINE CONTROL FLASH CODE
Input signal from pressure sen-
sor, induction manifold (cylin-
der 1) too low
Input signal from pressure sen-
sor, induction manifold (cylin-
der 1) too high
Flash code EFI Warning
lamp (MIL)
Possible cause
Input signal from pressure sen-
sor, induction manifold (cylin-
der 2) too low
Input signal from pressure sen-
sor, induction manifold (cylin-
der 2) too high
Flash code EFI Warning
lamp (MIL)
Possible cause
Input signal from intake air
temperatur sensor too low
Input signal from intake air
temperatur sensor too high
Flash code EFI Warning
lamp (MIL)
Possible cause
Input signal of pressure sensor
ambient air too low
Check pressure sensor, induction manifold (cylinder 1).
Check pressure sensor, induction manifold (cylinder 1).
11 EFI Warning lamp (MIL) flashes 1x long, 1x short
Action
Check pressure sensor, induction manifold (cylinder 2).
Check pressure sensor, induction manifold (cylinder 2).
13 EFI Warning lamp (MIL) flashes 1x long, 3x short
Action
Check the intake air temperature sensor.
Check the intake air temperature sensor.
14 EFI Warning lamp (MIL) flashes 1x long, 4x short
Action
Check pressure sensor, ambient air.
x
x
x
x
x
x
x
209